Contributo in atti di convegno, 2017, ENG, 10.1063/1.4995794

Test of 1D carbon-carbon composite prototype tiles for the SPIDER diagnostic calorimeter

Serianni G.; Pimazzoni A.; Canton A.; Dalla Palma M.; Delogu R.; Fasolo D.; Franchin L.; Pasqualotto R.; Tollin M.

1-9: Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4 - 35127 Padova, Italy; 2: Università degli Studi di Padova, Via 8 Febbraio 2, Padova, 35122, Italy.

Additional heating will be provided to the thermonuclear fusion experiment ITER by injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction at Consorzio REX in Padova (Italy), the production of negative ions will be studied and optimised. To this purpose the STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) diagnostic will be used to characterise the SPIDER beam during short operation (several seconds) and to verify if the beam meets the ITER requirement regarding the maximum allowed beam non-uniformity (below ±10%). The most important measurements performed by STRIKE are beam uniformity, beamlet divergence and stripping losses. The major components of STRIKE are 16 1D-CFC (Carbon matrix-Carbon Fibre reinforced Composite) tiles, observed at the rear side by a thermal camera. The requirements of the ID CFC material include a large thermal conductivity along the tile thickness (at least 10 times larger than in the other directions); low specific heat and density; uniform parameters over the tile surface; capability to withstand localised heat loads resulting in steep temperature gradients. So ID CFC is a very anisotropic and delicate material, not commercially available, and prototypes are being specifically realised. This contribution gives an overview of the tests performed on the CFC prototype tiles, aimed at verifying their thermal behaviour. The spatial uniformity of the parameters and the ratio between the thermal conductivities are assessed by means of a power laser at Consorzio RFX. Dedicated linear and non-linear simulations are carried out to interpret the experiments and to estimate the thermal conductivities; these simulations are described and a comparison of the experimental data with the simulation results is presented.

5th International Symposium on Negative Ions, Beams and Sources, NIBS 2016, pp. 060007-1–060007-7, Oxford, United Kingdom, September 12-16, 2016

Keywords

Metalloids, Testing for education, Computer simulation, National and international programs, Climatology

CNR authors

Serianni Gianluigi, Dalla Palma Mauro, Pasqualotto Roberto

CNR institutes

IGI – Istituto gas ionizzati

ID: 378696

Year: 2017

Type: Contributo in atti di convegno

Creation: 2017-11-23 17:53:00.000

Last update: 2021-01-27 16:48:01.000

External IDs

CNR OAI-PMH: oai:it.cnr:prodotti:378696

DOI: 10.1063/1.4995794

Scopus: 2-s2.0-85030107442

ISI Web of Science (WOS): 000417411100088