This paper deals with the standard deviation of reproducibility obtained from multiple Inter-Laboratory Tests (ILTs), whose average values were standardized in ISO 12999-1. The reproducibility obtained in this way is intended to be used for the declaration of uncertainty in test reports of building acoustics measurements. Therefore it is necessary that the declared uncertainty be representative of all the specimens, or products, that could be tested. This paper demonstrates that the new standard deviation sigmaR95 , introduced for the first time in ISO 12999-1, leads to an overcoverage with respect to the desired 95% coverage probability. Moreover, two other methods are presented, the former based on a Bayesian analysis and the latter on random variance and fixed mean, to demonstrate that the reproducibility standard deviation sigmaR , where the reproducibility variance sigma2R is the mean value of the variances of all the ILTs included in ISO 12999-1, is the natural choice for the declaration of uncertainty.
The uncertainty declaration of building acoustics measurements: How to select the uncertainty of reproducibility from inter-laboratory tests
C Scrosati;A Pievatolo;
2018
Abstract
This paper deals with the standard deviation of reproducibility obtained from multiple Inter-Laboratory Tests (ILTs), whose average values were standardized in ISO 12999-1. The reproducibility obtained in this way is intended to be used for the declaration of uncertainty in test reports of building acoustics measurements. Therefore it is necessary that the declared uncertainty be representative of all the specimens, or products, that could be tested. This paper demonstrates that the new standard deviation sigmaR95 , introduced for the first time in ISO 12999-1, leads to an overcoverage with respect to the desired 95% coverage probability. Moreover, two other methods are presented, the former based on a Bayesian analysis and the latter on random variance and fixed mean, to demonstrate that the reproducibility standard deviation sigmaR , where the reproducibility variance sigma2R is the mean value of the variances of all the ILTs included in ISO 12999-1, is the natural choice for the declaration of uncertainty.File | Dimensione | Formato | |
---|---|---|---|
prod_383716-doc_152809.pdf
solo utenti autorizzati
Descrizione: The Uncertainty Declaration of Building Acoustics Measurements: How to Select the Uncertainty of Reproducibility from Inter-Laboratory Tests
Tipologia:
Versione Editoriale (PDF)
Dimensione
136.23 kB
Formato
Adobe PDF
|
136.23 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
prod_383716-doc_189313.pdf
accesso aperto
Descrizione: The Uncertainty Declaration of Building Acoustics Measurements: How to Select the Uncertainty of Reproducibility from Inter-Laboratory Tests
Tipologia:
Versione Editoriale (PDF)
Dimensione
192 kB
Formato
Adobe PDF
|
192 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.