Articolo in rivista, 2020, ENG, 10.3390/bios10120202
Rosario Iemmolo; Valentina La Cognata; Giovanna Morello; Maria Guarnaccia; Mariamena Arbitrio; Enrico Alessi; Sebastiano Cavallaro;
Institute for Biomedical Research and Innovation, National Research Council, Via Paolo Gaifami, 18-95126 Catania, Italy; r.iemmolo@isn.cnr.it (R.I.); valentina.lacognata@cnr.it (V.L.C.); g.morello@isn.cnr.it (G.M.); maria.guarnaccia@cnr.it (M.G.) 2 Institute for Biomedical Research and Innovation, National Research Council, 88100 Catanzaro, Italy; mariamena.arbitrio@cnr.it 3 Analog, MEMS & Sensor Group Health Care Business Development Unit, STMicroelectronics, Stradale Primosole, 50-95126 Catania, Italy; enrico.alessi@st.com
Background: Antineoplastic agents represent the most common class of drugs causing Adverse Drug Reactions (ADRs). Mutant alleles of genes coding for drug-metabolizing enzymes are the best studied individual risk factors for these ADRs. Although the correlation between genetic polymorphisms and ADRs is well-known, pharmacogenetic tests are limited to centralized laboratories with expensive or dedicated instrumentation used by specialized personnel. Nowadays, DNA chips have overcome the major limitations in terms of sensibility, specificity or small molecular detection, allowing the simultaneous detection of several genetic polymorphisms with time and costs-eective advantages. In this work, we describe the design of a novel silicon-based lab-on-chip assay able to perform low-density and high-resolution multi-assay analysis (amplification and hybridization reactions) on the In-Check platform. Methods: The novel lab-on-chip was used to screen 17 allelic variants of three genes associated with adverse reactions to common chemotherapeutic agents: DPYD (Dihydropyrimidine dehydrogenase), MTHFR (5,10-Methylenetetrahydrofolate reductase) and TPMT (Thiopurine S-methyltransferase). Results: Inter- and intra assay variability were performed to assess the specificity and sensibility of the chip. Linear regression was used to assess the optimal hybridization temperature set at 52 C (R2 0.97). Limit of detection was 50 nM. Conclusions: The high performance in terms of sensibility and specificity of this lab-on-chip supports its further translation to clinical diagnostics, where it may eectively promote precision medicine.
Biosensors (Basel) 10 (202)
pharmacogenetics; lab-on-chip; microfluidics; biosensors; In-Check platform; adverse drug reaction
Iemmolo Rosario, Morello Giovanna, Alessi Enrico Rosario, Arbitrio Mariamena, Cavallaro Sebastiano, Guarnaccia Maria, La Cognata Valentina
ID: 438869
Year: 2020
Type: Articolo in rivista
Creation: 2020-12-12 23:29:43.000
Last update: 2021-12-23 12:27:52.000
CNR institutes
External IDs
CNR OAI-PMH: oai:it.cnr:prodotti:438869
DOI: 10.3390/bios10120202