SPIDER, the full size ITER NBI ion source, aims to prove the ITER requirements in terms of the ion source performance, a beam uniformity better than 90% and a low beam divergence. The SPIDER experiment can operate in deuterium, thus producing beam-target D-D fusion neutron emissions. These emissions can be used to evaluate the beam uniformity as well as machine parameter dependence, since the neutron flux is proportional to the beam power. To this end, a new neutron diagnostic array, consisting of a mix of seven crystal, plastic, and liquid scintillators, has been installed externally on the beam dump side of the vessel. Six of them are capable of neutron/gamma discrimination and are positioned to study the beam uniformity and allow parametric comparisons. An NaI scintillator-based gamma detector allows for the energy spectra reconstruction of incident gamma rays without neutron interference. In this work, the scintillator array's capability and arrangement, together with first results achieved during the deuterium campaigns performed in SPIDER, are presented and discussed.

Preliminary parametric analysis of the first neutrons measured with a scintillator array at SPIDER

Zuin M;Croci G;Muraro A;Perelli Cippo E;Grosso G;Rigamonti D;Rebai M;Pasqualotto R;Tardocchi M
2021

Abstract

SPIDER, the full size ITER NBI ion source, aims to prove the ITER requirements in terms of the ion source performance, a beam uniformity better than 90% and a low beam divergence. The SPIDER experiment can operate in deuterium, thus producing beam-target D-D fusion neutron emissions. These emissions can be used to evaluate the beam uniformity as well as machine parameter dependence, since the neutron flux is proportional to the beam power. To this end, a new neutron diagnostic array, consisting of a mix of seven crystal, plastic, and liquid scintillators, has been installed externally on the beam dump side of the vessel. Six of them are capable of neutron/gamma discrimination and are positioned to study the beam uniformity and allow parametric comparisons. An NaI scintillator-based gamma detector allows for the energy spectra reconstruction of incident gamma rays without neutron interference. In this work, the scintillator array's capability and arrangement, together with first results achieved during the deuterium campaigns performed in SPIDER, are presented and discussed.
2021
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
SPIDER
fusion neutron diagnostics
scintillators
File in questo prodotto:
File Dimensione Formato  
prod_456319-doc_176569.pdf

solo utenti autorizzati

Descrizione: Abstract Preliminary parametric analysis of the first neutrons measured with a scintillator array at SPIDER
Tipologia: Versione Editoriale (PDF)
Dimensione 78.53 kB
Formato Adobe PDF
78.53 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/397412
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact