Abstract in atti di convegno, 2021, ENG
Dal Molin A.; Rigamonti D.; Partesotti G.; Andersson-Sunden E.; Conroy S.; Ericsson G.; Giacomelli L.; Hagg L.; Kurki-Suonio T.; Nocente M.; Panontin E.; Rebai M.; Snicker A.; Tardini G.; Tardocchi M.; Gorini G.; ASDEX Upgrade Team
Department of Physics, Università degli Studi di Milano-Bicocca, Milan, Italy; Istituto per la Scienza e Tecnologia dei Plasmi (ISTP), CNR, Milan, Italy; Department of Physics, Università degli Studi di Modena e Reggio Emilia, Modena, Italy; Department of Physics and Astronomy, Uppsala University, Sweden; Department of Applied Physics, Aalto University, Espoo, Finland; Max Planck Institute for Plasma Physics, Garching, Germany.
Neutron emission spectroscopy is an established diagnostic for thermonuclear plasmas. The best proven technique is based on time of flight measurements, as they provide superior performance, but are also rather demanding in terms of machine interface requirements. The recent development of novel compact neutron spectrometers with good n/? discrimination capability made it possible to? discrimination capability made it possible to perform neutron spectroscopy measurements also in machines where there is limited space for a large installation, which is often the case of medium-sized tokamaks. In order to improve the suite of neutron diagnostics at the ASDEX Upgrade tokamak, a C7LYC based detector optimized for 2.5 MeV neutrons spectroscopy has been recently developed. The instrument, named COSMONAUT (COmpact Spectrometer for Measurements Of Neutrons at the ASDEX Upgrade Tokamak) was developed to measure the 2.5 MeV neutron spectrum from deuterium plasmas at the tokamak ASDEX Upgrade and is based on a former prototype detector developed for EAST. In this contribution, we present calculations of synthetic neutron spectra that may be measured in deuterium plasmas heated by neutral beam injection at the ASDEX Upgrade tokamak. These calculations are obtained by simulating the beam slowing down distribution paired with neutron production and transport to the detector position. Simulation results are then used to assess COSMONAUT detection capability.
European Conference on Plasma Diagnostics - ECPD 2021, Virtual Conference, 7-11 June 2021
C7LYC, compact neutron spectrometer, ASDEX Upgrade, tokamak
Rigamonti Davide, Gorini Giuseppe, Nocente Massimo, Dal Molin Andrea, Rebai Marica, Tardocchi Marco
ID: 465236
Year: 2021
Type: Abstract in atti di convegno
Creation: 2022-03-17 15:36:31.000
Last update: 2022-11-18 12:02:52.000
CNR institutes
External links
OAI-PMH: Dublin Core
OAI-PMH: Mods
OAI-PMH: RDF
URL: https://www.clpu.es/sites/default/files/Andrea_Dal_Molin.pdf
External IDs
CNR OAI-PMH: oai:it.cnr:prodotti:465236