Rapporto di progetto (Project report), 2022, ENG
Matteo Mastellone, Alessandro Bellucci, Marco Girolami, Valerio Serpente, Antonello Ranieri e Daniele M. Trucchi
ISM-CNR, ISM-CNR, ISM-CNR, ISM-CNR, IC-CNR, ISM-CNR
The following technical report discloses the results of the thermal test carried out on the single crystal diamond matrix detector prototype for the ITER Radial Neutron Camera (RNC) diagnostics system.
detector, diamond, x-ray, ITER, diamond detectors, Radial Neutron Camera, Ionizing radiation detectors, High temperature
Mastellone Matteo, Serpente Valerio, Ranieri Antonello, Trucchi Daniele Maria, Girolami Marco, Bellucci Alessandro
IC – Istituto di cristallografia, ISM – Istituto di struttura della materia
ID: 469863
Year: 2022
Type: Rapporto di progetto (Project report)
Creation: 2022-08-11 11:48:33.000
Last update: 2023-03-14 15:55:07.000
External IDs
CNR OAI-PMH: oai:it.cnr:prodotti:469863