2020, Articolo in rivista, ENG
Scano A.; Pirovano I.; Manunza M.E.; Spinelli L.; Contini D.; Torricelli A.; Re R.
The effect of sustained fatigue during an upper limb isometric exercise is presented to investigate a group of healthy subjects with simultaneous time-domain (TD) NIRS and surface electromyography (sEMG) recordings on the deltoid lateralis muscle. The aim of the work was to understand which TD-NIRS parameters can be used as descriptors for sustained muscular fatigue, focusing on the slow phase of this process and using median frequency (MF) computed from sEMG as gold standard measure. It was found that oxygen saturation and deoxy-hemoglobin are slightly better descriptors of sustained fatigue, than oxy-hemoglobin, since they showed a higher correlation with MF, while total-hemoglobin correlation with MF was lower.
DOI: 10.1364/BOE.403976
2019, Articolo in rivista, ENG
Scano A.; Zanoletti M.; Pirovano I.; Spinelli L.; Contini D.; Torricelli A.; Re R.
In this review, we present an overview of the applications and computed parameters of electromyography (EMG) and near-infrared spectroscopy (NIRS) methods on patients in clinical practice. The eligible studies were those where both techniques were combined in order to assess muscle characteristics from the electrical and hemodynamic points of view. With this aim, a comprehensive screening of the literature based on related keywords in the most-used scientific data bases allowed us to identify 17 papers which met the research criteria. We also present a brief overview of the devices designed specifically for muscular applications with EMG and NIRS sensors (a total of eight papers). A critical analysis of the results of the review suggests that the combined use of EMG and NIRS on muscle has been only partially exploited for assessment and evaluation in clinical practice and, thus, this field shows promises for future developments.
DOI: 10.3390/app9152952
2017, Articolo in rivista, ENG
M. Buttafava and E. Martinenghi and D. Tamborini and D. Contini and A. D. Mora and M. Renna and A. Torricelli and A. Pifferi and F. Zappa and A. Tosi
This paper presents a complete, compact, and low power consumption instrument designed for time-domain near-infrared spectroscopy. It employs two custom-designed pulsed diode lasers (operating at 830 and 670 nm, with average optical power higher than 2 mW at 40 MHz repetition frequency), a single-photon detection module (based on a 1 mm2 active area silicon photomultiplier), and a custom time-to-digital converter with 10 ps time resolution. The system experimental characterization shows an instrument response function narrower than 300 ps (full-width at half maximum), with measurement stability better than ?1% over several hours of operation. The instrument, which is housed into a compact aluminum case (size 200 ? 160 ? 50 mm3), is specifically tailored for portability and ease of operation, hence fostering the diffusion of time-domain diffuse optics techniques. Thanks to a total power consumption lower than 10 W, this system is suitable for battery operation, thus enabling on-field measurements.
2017, Articolo in rivista, ENG
Binzoni, Tiziano; Sassaroli, Angelo; Torricelli, Alessandro; Spinelli, Lorenzo; Farina, Andrea; Durduran, Turgut; Cavalieri, Stefano; Pifferi, Antonio; Martelli, Fabrizio
The depth sensitivity functions for AC amplitude, phase (PH) and DC intensity signals have been obtained in the frequency domain (where the source amplitude is modulated at radio-frequencies) by making use of analytical solutions of the photon diffusion equation in an infinite slab geometry. Furthermore, solutions for the relative contrast of AC, PH and DC signals when a totally absorbing plane is placed at a fixed depth of the slab have also been obtained. The solutions have been validated by comparisons with gold standard Monte Carlo simulations. The obtained results show that the AC signal, for modulation frequencies < 200 MHz, has a depth sensitivity with similar characteristics to that of the continuous-wave (CW) domain (source modulation frequency of zero). Thus, the depth probed by such a signal can be estimated by using the formula of penetration depth for the CW domain (Sci. Rep. 6, 27057 (2016)). However, the PH signal has a different behavior compared to the CW domain, showing a larger depth sensitivity at shallow depths and a less steep relative contrast as a function of depth. These results mark a clear difference in term of depth sensitivity between AC and PH signals, and highlight the complexity of the estimation of the actual depth probed in tissue spectroscopy.
DOI: 10.1364/BOE.8.002990
2016, Articolo in rivista, ENG
Re, Rebecca; Martinenghi, Edoardo; Dalla Mora, Alberto; Contini, Davide; Pifferi, Antonio; Torricelli, Alessandro
We report the development of a compact probe for time-domain (TD) functional near-infrared spectroscopy (fNIRS) based on a fast silicon photomultiplier (SiPM) that can be put directly in contact with the sample without the need of optical fibers for light collection. We directly integrated an avalanche signal amplification stage close to the SiPM, thus reducing the size of the detection channel and optimizing the signal immunity to electromagnetic interferences. The whole detection electronics was placed in a plastic screw holder compatible with the electroencephalography standard cap for measurement on brain or with custom probe holders. The SiPM is inserted into a transparent and insulating resin to avoid the direct contact of the scalp with the 100-V bias voltage. The probe was integrated in an instrument for TD fNIRS spectroscopy. The system was characterized on tissue phantoms in terms of temporal resolution, responsivity, linearity, and capability to detect deep absorption changes. Preliminary in vivo tests on adult volunteers were performed to monitor hemodynamic changes in the arm during a cuff occlusion and in the brain cortex during a motor task. (C) The Authors.